Stepper Motors

CDA's stepper motors provide an incremental step output depending on the excitation logic applied to the motor windings. These stepper motors provide high running torque capacity per unit weight and size. Their high performance and excellent stepping accuracy make these components ideal in open loop positioning systems, incremental rate control systems, or limited angle rotary switched. Samarium combalt rare earth magnets, high grade stainless steel construction, and class H225 insulation system assure rugged, reliable performance under the most severe operating conditions.

Type 03 Performance
Motor
Code
Step
Angle
Holding Data Low Pulse Rate
Torque
Maximum Power Output No Load
Torque Power
Input
Rate Torque Power
Input
Response Slew
Rate Power Rate
Degrees OZ-IN Nmm Watts OZ-IN Nmm PPS RPM OZ-IN Nmm Watts PPS RPM Watts PPS RPM
12-2P2-06 90 1.06 7.18 6 0.75 5.3 130 1950 0.38 2.6 4 260 3900 2 345 5175
12-2P2-10 90 1.37 9.67 10 0.97 6.8 140 2100 0.48 3.4 8 280 4200 6 470 7050
12-2P2-20 90 1.94 13.7 20 1.37 9.7 175 2625 0.68 4.8 16 350 5250 14 700 10500
12-2P2-30 90 2.37 16.7 30 1.68 11.9 210 3150 0.84 5.9 24 420 6300 21 900 13500
12-2P4-06 45 1.92 13.6 6 1.36 9.6 200 1500 0.68 4.8 4 400 3000 3 455 3412
12-2P4-10 45 2.48 17.5 10 1.75 12.4 240 1800 0.88 6.2 8 480 3600 6 600 4500
12-2P4-20 45 3.51 24.8 20 2.48 17.5 290 2175 1.24 8.8 16 580 4350 12 900 6750
12-2P4-30 45 4.31 30.4 30 3.05 21.5 330 2475 1.52 10.7 24 660 4950 19 1150 8625
12-2P6-06 30 2.22 15.7 6 15.7 11.1 262 1310 0.78 5.5 4 525 2625 3 600 3000
12-2P6-10 30 2.87 20.3 10 20.3 14.3 312 1560 1.02 7.2 8 625 3125 5 815 4075
12-2P6-20 30 4.06 28.7 20 28.7 20.3 380 1900 1.44 10.2 16 760 3800 12 1200 6000
12-2P6-30 30 4.97 35.1 30 35.1 24.8 450 2250 1.76 12.4 24 900 4500 18 1600 8000

Notes:
1. Source voltages as required.
2. Other performance characteristics and power levels available on request.
3. Performance tabulated at +25° C unit temperature.
4. Note: the 6 pole two phase is the preferred standard.

Type 03 Performance
Motor
Code
Step
Angle
Holding Data Low Pulse Rate
Torque
Maximum Power Output No Load
Torque Power
Input
Rate Torque Power
Input
Response Slew
Rate Power Rate
Degrees OZ-IN Nmm Watts OZ-IN Nmm PPS RPM OZ-IN Nmm Watts PPS RPM Watts PPS RPM
12-3P2-06 60 1.22 8.61 6 0.86 6.07 115 1150 0.43 3.04 4 330 3300 3 3 4000
12-3P2-10 60 1.58 11.2 10 1.12 7.91 190 1900 0.56 3.95 8 380 3800 5 5 5350
12-3P2-20 60 2.24 15.8 20 1.58 11.2 232 2320 0.79 5.58 16 465 4650 12 12 8000
12-3P2-30 60 2.74 19.3 30 1.94 13.7 270 2700 0.97 6.85 24 540 5400 18 18 10250
12-3P4-06 30 2.08 14.7 6 1.47 10.4 263 1315 0.74 5.22 4 526 2630 3 600 3000
12-3P4-10 30 2.69 19 10 1.9 13.4 313 1565 0.95 6.71 8 626 3130 5 816 4080
12-3P4-20 30 3.8 26.8 20 2.69 19 380 1900 1.34 9.46 16 760 3800 12 1200 6000
12-3P4-30 30 4.66 32.9 30 3.29 23.2 450 2250 1.64 11.6 24 900 4500 18 1600 8000

Notes:
1. Source voltages as required.
2. Other performance characteristics and power levels available on request.
3. Performance tabulated at +25° C unit temperature.
4. Note: the 6 pole two phase is the preferred standard.